MAHR Millimar Measuring amplifiers

MAHR Millimar Measuring amplifiers

  • Millimar 1901 TA Amplifier with analog output

Millimar 1901 TA Amplifier with analog output

 

  • Output voltage - ± 10 V (optional: ± 5 V / 0 V to 10 V) at end of measuring range (output voltage can be set using jumpers)
  • There is also an output signal available in the form of a current of ± 5 mA at the end of the measuring range
  • Supply voltage - 24 VDC
  • The housing of the 1901 TA is designed to fit inside the machine room
  • Connection - One input for Mahr-compatible inductive probes

Technical data

Order no.Product typeDisplayMeasuring range, inductive probeProbe inputsCompatibilityFeaturesResponse time analog outputData transmission rateError limit, analog outputAnalog outputEnergy supplyIP protection category
5319011

1901 TA

No display, amplifier with analog output

± 125 / ± 250 / ± 500 / ± 1000 / ± 2000

1

Mahr

1

0.01 s

90 Hz

+/- 0,3 %

  • 1 output Voltage: at end of range +/- 10 V, option: +/- 5 V / 0-10 V
  • 1 current output: at end of range +/- 5mA

24 V =

IP 54