MMQ 400-2Z= 900 mm X= 280 mm | 5440781 - MMQ 400-2/280/500/CNC/Scale | 5440780 - MMQ 400-2/180/350/CNC/Scale | |
Roundness deviation (µm+µm/mm measuring height) * | 0,01 + 0,00025 | 0,01 + 0,00025 | 0,01 + 0,00025 |
Roundness deviation (µm+µm/mm measuring height) ** | 0,02 + 0,0005 | 0,02 + 0,0005 | 0,02 + 0,0005 |
Axial runout deviation (µm+µm/mm measuring radius) * | 0,02 + 0,0001 | 0,02 + 0,0001 | 0,02 + 0,0001 |
Axial runout deviation (µm+µm/mm measuring radius) ** | 0,04 + 0,0002 | 0,04 + 0,0002 | 0,04 + 0,0002 |
Centering and tilting table | automatic | automatic | automatic |
Table diameter (mm) | 285 | 285 | 285 |
Table load capacity, centered (N) | 400 | 600 | 600 |
Speed (rpm) 50 Hz / 60 Hz | 0.2-15 | 0.2-15 | 0.2-15 |
Measuring path, motorized Z (mm) | 900 | 500 | 350 |
Straightness deviation / 100 mm measuring path (µm)**, Z axis | 0.15 | 0.15 | 0.15 |
Straightness deviation / total measuring path (µm)**, Z axis | 0.9 | 0.4 | 0.3 |
Parallelism deviation Z-/C axis in tracing direction, measuring path (µm) | 2 | 0.8 | 0.5 |
Measuring speed (mm/s), Z axis | 0,1-30 | 0,1-30 | 0,1-30 |
Positioning speed (mm/s), Z axis | 0,5 -100 | 0,5 -100 | 0,5 -100 |
Measuring path, motorized X (mm) | 280 | 280 | 180 |
Straightness deviation /av. 100 mm measuring path (µm)**, X axis | 0.5 | 0.5 | 0.4 |
Straightness deviation / total measuring path (µm)**, X axis | 1.5 | 1.5 | 0.8 |
Perpendicularity X/C axis, measuring path (µm) | 2 | 2 | 1 |
Positioning speed (mm/s), X axis | 0,5-30 | 0,5-30 | 0,5-30 |
Measuring speed (mm/s), X axis | 0,5-10 | 0,5-10 | 0,5-10 |
Footer text | * Values as maximum deviation from LSC reference circle, filter 15 undulations/revolution.** All values in accordance with DIN ISO 1101 at 20°C ±1°C in a vibration-neutral environment, filter 15 undulations/revolution LSC or 2.5 mm LSS, 5 rpm or 5 mm/s and standard probe arm with ball diameter 3 mm. Proof at the standard using error separation techniques. Given the number of different options available, only a few machines are described here by way of example. Technical data for "your" MMQ is available from Mahr on request. | * Values as maximum deviation from LSC reference circle, filter 15 undulations/revolution.** All values in accordance with DIN ISO 1101 at 20°C ±1°C in a vibration-neutral environment, filter 15 undulations/revolution LSC or 2.5 mm LSS, 5 rpm or 5 mm/s and standard probe arm with ball diameter 3 mm. Proof at the standard using error separation techniques. Given the number of different options available, only a few machines are described here by way of example. Technical data for "your" MMQ is available from Mahr on request. | * Values as maximum deviation from LSC reference circle, filter 15 undulations/revolution.** All values in accordance with DIN ISO 1101 at 20°C ±1°C in a vibration-neutral environment, filter 15 undulations/revolution LSC or 2.5 mm LSS, 5 rpm or 5 mm/s and standard probe arm with ball diameter 3 mm. Proof at the standard using error separation techniques. Given the number of different options available, only a few machines are described here by way of example. Technical data for "your" MMQ is available from Mahr on request. |